LED Codes
LED Codes
Serial ROM
LED Codes
The system displays a series of hexadecimal codes at the
beginning of the power-up test. The codes, the corresponding test
description, and possible reasons for a test failure are described
in Table 14–1.
Note
See Table 5–2 for a list of the LED displays and
corresponding hex codes for the DEC 3000 Model 600
/600S AXP system.
Table 14–1 Power-Up Test Serial ROM Codes
LED
Code
Test Description
Reason for Failure
FF
Set all 8 Multiplexer Control
Registers (MCRs) to 128M.
MCR did not read back as expected
(fatal error, branches to SROM
miniconsole).
FE
Mapping out an MCR per
macrocoders manual (only appears if
an error occurs).
MCR did not read back as expected
(fatal error, branches to SROM
miniconsole).
FD
Memory sizing completed.
All MCRs mapped out (no memory
detected - fatal error, branches to
SROM miniconsole).
FC
Mapping an MCR.
Only MCR did not read back as
expected (fatal error, branches to
SROM miniconsole).
FB
Memory configuration completed.
Should never stop here.
FA
Memory test with non-BCACHE bit
SET, Dcache OFF, and mchk enabled
If read as .NE. write, send error dump
to SROM port and branch to SROM
miniconsole.
(continued on next page)
14–2
Summary of Contents for DEC 3000 600 AXP
Page 57: ...BA47X AA Vertical Floor Stand Figure 3 8 Removing the Mounting Plate MLO 011165 4 5 3 12...
Page 60: ...System Cover Figure 3 9 Removing the System Cover MLO 008608 2 2 1 0 1 3 15...
Page 65: ...Removable Media Devices Figure 3 11 Loosening the Screws on the Bracket MLO 011167 1 3 20...
Page 81: ...I O Board Figure 3 18 Removing the I O Board 1 2 3 3 4 MLO 011172 3 36...
Page 149: ...Front View Figure 6 1 Front View Line In 1 2 3 4 5 MLO 007553 7 8 9 10 11 12 6 14 13 6 6...
Page 152: ...Rear View Figure 6 2 Rear View ISDN S3 1 3 4 5 6 8 10 11 MLO 010854 2 1 0 3 4 5 2 7 9 6 9...
Page 189: ...Power Supply Figure 8 10 Removing the Power Supply MLO 011224 3 4 2 8 20...
Page 193: ...RZxx Disk Drives Figure 8 11 Removing an RZxx Drive 1 2 4 3 MLO 011225 8 24...
Page 199: ...I O Module Figure 8 14 I O Module Cable Connections 2 1 0 MLO 011227 ISDN S3 3 4 5 1 8 30...
Page 200: ...I O Module Figure 8 15 Removing the I O Module Side View MLO 011228 2 3 4 5 6 8 31...
Page 204: ...Fans Figure 8 17 Removing a Fan 1 Front 2 3 4 MLO 011229 8 35...
Page 207: ...Memory Mother Board Figure 8 18 Removing a Memory Mother Board MLO 011230 1 2 8 38...
Page 210: ...Memory Module Figure 8 19 Removing SIMMs 1 2 MLO 011231 8 41...
Page 430: ...Setting a Unique SCSI Address the OpenVMS AXP and DEC OSF 1 AXP operating systems 16 4...
Page 461: ......