Power-Up 2-15
2.6
XSROM Errors Reported
The XSROM reports B-cache test errors and memory test errors. It also
reports a warning if memory is illegally configured.
Example 2–1 XSROM Errors Reported at Power-Up
B-cache Error (CPU Error)
TEST ERR on cpu0
#CPU running the test
FRU
cpu0
err#
2
tst#
11
exp:
5555555555555555
#Expected data
rcv:
aaaaaaaaaaaaaaaa
#Received data
adr:
ffff8
#B-cache location
error #occurred
Memory Error (Memory Module Indicated)
20..21..
TEST ERR on cpu0
#CPU running test
FRU:
MEM1L
#Low member of memory pair 1
err#
c
tst#
21
22..23..24..Memory testing complete on cpu0
Memory Configuration Error (Operator Error)
ERR! mem
_
pair0 misconfigured
ERR! mem
_
pair1 card size mismatch
ERR! Mem_pair6 card type mismatch
ERR! mem
_
pair1 EMPTY
FEPROM Failures (PCI Error)
Sctr 1 -PAL headr PTTRN fail
Sctr 1 -PAL headr CHKSM fail
Sctr 1 -PAL code CHKSM fail
Sctr 3 -CONSLE headr PTTRN fail
Sctr 3 -CONSLE headr CHKSM fail
Sctr 3 -CONSLE code CHKSM fail