System Overview 1-25
The 1200 system allows both local and remote control. A set of switches enables or
disables remote control.
The switches and their functions are:
Switch
Condition
Function
1 EN RCM
On
Off
Allows remote system control
Does not allow remote system control
2 Modem Off
On
Off
Disables the RCM modem port
Enable the RCM modem port
3 RPD DIS
On
Off
Disables remote power down
Enables remote power down
4 SET DEF
On
Off
Resets the RCM microprocessor defaults
Allows use of conditions set by the user
To allow complete remote control the user would put switch 1, EN RCM, on; and
switches 2, 3, and 4 off.
See Appendix C for information on controlling the system remotely.
The remote console monitor connects to a modem through the modem port on the
bulkhead. The RCM uses VAUX power provided by the system power supplies.
The standard I/O ports (keyboard, mouse, COM1 and COM2 serial ports, and
parallel ports) are on the same bulkhead.