MAX II
Bolt Tension Monitor
75
This section assumes that a temperature sensor has not been connected
and the temperature mode is set to “manual”. If the temperature sensor
was connected and activated, the length of the bolt should match within
tolerance.
Note:
User has selected this section because the
MAX II
, transducer, or
transducer cable has not changed and the elongation is outside the tolerance of
+/- .0005”.
Note:
This section assumes that a group
CAL DATA
has been created and
opened/active, as outlined in section 8.3.
1) Press the
MEAS
key once to activate measure menu items. Press the
MEAS
key multiple times to move down and the
ESC
key multiple times to
move up until the
LOG
cell is highlighted. Alternatively, press the
UP
and
DOWN
arrow keys multiple times using the left button wheel.
Note:
Pressing the
key will immediately display the
CAL DATA
group.
2) Press the
ENTER
key to display the
Group View Box
.
3) Press the
UP, DOWN, LEFT, & RIGHT
arrow keys using the left button
wheel to scroll the stored readings and corresponding display view. Notice