MAX II
Bolt Tension Monitor
31
GATE 1:
Gates allow the user to view a specific measurement range, or sections of
the waveform, and ignore others. The Gate1 feature adjusts the start of the gate,
according to time/distance. Gate 1 can be used in all pulse-echo and echo-echo
measurement modes. Refer to page 143 for further info.
THRESHOLD1:
Enables the user to set the sensitivity level of Gate1. The amplitude
of the signal must reach or exceed the threshold level before a measurement is
detected. Refer to page 143 for further info.
GATE 2:
Provides the user with the ability to delay the starting point of Gate2, a
specific distance from the first detection point found inside of the boundaries of the
Gate 1 settings. If no detection is found, the Gate1 width value is used as a starting
value for Gate2. Refer to page 143 for further info.
THRESHOLD2:
Enables the user to set the sensitivity level of Gate2. The amplitude
of the signal must reach or exceed the threshold level before a measurement is
detected. Refer to page 143 for further info.
GATE 3:
Provides the user with the ability to delay the starting point of Gate3, a
specific distance from the first detection point found inside of the boundaries of the
Gate 2 settings. If no detection is found, the Gate2 width value is used as a starting
value for Gate3. Refer to page 143 for further info.
THRESHOLD3:
Enables the user to set the sensitivity level of Gate3. The amplitude
of the signal must reach or exceed the threshold level before a measurement is
detected. Refer to page 143 for further info.
4.8 AUTO – Menu
AUTO SET:
Automatically locates the detection point if the measurement is out of the
viewable display area. Used when measuring reference lengths only. Refer to
section 12.9 for further info.
APPROX LEN:
In order for the user to use the Auto Set feature, an approximate
length of the fastener must be entered. The approximate length gives the
MAX II
some idea of where to turn on the receiver and look for the detection, or end of the
bolt. This sub menu item enables the user to edit the effective length at anytime.
Refer to section 12.9 for further info.
MEASURE MODE:
Used to select the measurement mode for different application
requirements. The mode options are P-E (pulse-echo), E-E (echo-echo), or E-EV
(echo-echo-echo). Refer to page 143 for further info.