Dakota Ultrasonics
168
4) Press the
MEAS
key to return to the measurement screen and begin taking
readings.
13.11 Alarm Mode
The
Alarm Mode
feature of the
MAX II
provides the user with a method of setting
tolerances, or limits, for a particular fastener. This feature may be used for a variety
of applications to verify the stretch on a fastener is within predetermined tolerances.
There are two limits, or alarm values, that can be setup in the
MAX II
–
ALARM LOW
and
ALARM HIGH
limits. However, the user may choose to activate and utilize only
one of the limit values, depending on their specific application requirements. The
procedures to use the
ALARM MODE
feature are outlined below:
For quick access and editing, refer to navigating the Hot Menus page 36.
Toggle Alarm (on/off)
1) Press the
MENU
key once to activate the menu items tab. Press the
MENU
key multiple times to tab right, and the
ESC
key multiple times to tab left,
until the
UTIL
menu is highlighted and displaying the submenu items.
Alternatively, press the
LEFT
and
RIGHT
arrow keys multiple times
using the left button wheel.
2) Use the
UP
and
DOWN
arrow keys multiple times using the left button
wheel to scroll through the sub menu items until
ALARM
is highlighted.
3) Use the
LEFT
and
RIGHT
arrow keys multiple times on the right button
wheel to toggle the
ALARM
on/off/audible.