Dakota Ultrasonics
156
2) Press the
UP
and
DOWN
arrow keys multiple times using the left
button wheel to scroll through the sub menu items until
AUTO SET
is
highlighted.
3) Apply a drop of couplant to the bolt or transducer, and attach it to one end of
the bolt. Rotate the transducer clockwise and counter clockwise applying a
small amount of pressure to eliminate any excess couplant between the
transducer and bolt surface.
Be sure to always place the transducer in the
same location
.
This will help to eliminate any potential measurement errors
caused by changing the sound path.
4) Press the
ENTER
key to automatically adjust the display settings and bring
the waveform into view.
5) Once the signal is displayed, press the
MEAS
key to return to measurement
mode.
12.10 Unloaded Length and Elongation Measurements
The entire procedure to effectively prepare, setup, and measure is located in the
quick start guide in Chapter Two. Please refer to this section for further instructions.