MAX II
Bolt Tension Monitor
125
22)
Repeat Steps
1 – 21
for sample bolts 2 & 3.
Now that we have measured and documented three sample bolts, we’re now ready to
run the vector or regression calculation to determine a load factor and offset
(regression only).
Running a Regression or Vector
1) Press the
MENU
key multiple times to tab right and the
ESC
key multiple
times to tab left until the
CAL
menu is highlighted and displaying the
submenu items. Alternatively, press the
LEFT
and
RIGHT
arrow keys
multiple times using the left button wheel.
2) Press the
UP
and
DOWN
arrow keys multiple times using the left
button wheel to scroll through the sub menu items until
LOAD CAL CALC
is
highlighted.
3) Press the
ENTER
key to run the calculation and display the confirmation
screen.
Note:
The regression or vector coefficient will be displayed. The closer this
number is to 1, the better the fit, or least amount of error.
4) Press the
OK
key to accept the calculation, or the
ESC
key to cancel and
return to the
CAL
menu.
Summary of Contents for MAX II