MAX II
Bolt Tension Monitor
167
13.10 Polarity
Refer to section 12.7 ,interpreting the Waveform, for a detailed explanation on how to
select the proper polarity. It’s also important to note that the
MAX II
auto set feature
will automatically select and set the polarity, but it’s important to review, understand,
and check that
MAX II
selected the proper polarity. The user may choose to
manually override the initial selection. The following procedures are the necessary
steps to change the polarity only.
For quick access and editing, refer to navigating the Hot Menus page 36.
Toggle Polarity (+/-)
Note:
Before toggling the
Polarity
, the
MAX II
should be set to the
RF
display
view option. The
RF
view will give the user the best opportunity to correctly
view the positive and negative cycles of the waveform. Please refer section
12.2 for information on selecting the
Display Views
.
1) Press the
MENU
key once to activate the menu items tab. Press the
MENU
key multiple times to tab right, and the
ESC
key multiple times to tab left,
until the
TUNE
menu is highlighted and displaying the submenu items.
Alternatively, press the
LEFT
and
RIGHT
arrow keys multiple times
using the left button wheel.
2) Use the
UP
and
DOWN
arrow keys multiple times using the left button
wheel to scroll through the sub menu items until
POLARITY
is highlighted.
3) Use the
LEFT
and
RIGHT
arrow keys multiple times on the right button
wheel to toggle the
POLARITY
negative or positive.
Summary of Contents for MAX II
Page 2: ......
Page 7: ......
Page 8: ......
Page 54: ...Dakota Ultrasonics 46 Figure 6 Reflection in a bending bolt ...