MAX II
Bolt Tension Monitor
11
This section allows the user the ability to select a material from a list of preset
material types. Keep in mind that we are measuring elongation only. If your
material is not in the list, select a similar material type. When measuring in
elongation mode, the measurement consists of a difference equation only
(Loaded Length – Unloaded Length =
Length). Therefore, it doesn’t matter if
the ultrasonic length is different from the actual physical length, because the
Length will be the same. Example: 2.0080” physical loaded length – 2.0000”
physical unloaded length = 0.0080”
Length which is equivalent to 2.1080”
ultrasonic loaded length – 2.1000” ultrasonic unloaded length = 0.0080”
Length.
1) Press the
UP
and
DOWN
arrow keys multiple times using the left
button wheel to scroll through the sub menu items until
TYPE
is highlighted.
2) Press the
ENTER
key to display the list material types.
3) Press the
UP
and
DOWN
arrow keys multiple times using the left
button wheel to scroll through the material list until the appropriate type is
highlighted.
4) Press the
ENTER
key to display the confirmation screen.
5) Press the
OK
key to select the type and return to the menu screen, or
ESC
to cancel selecting the material type.