62
AIR CONDITIONING
62 - 19
A
C
B
Thermostatic expansion valve
Its function is to reduce the refrigerant fluid
pressure at the evaporator entrance, to a default
value. In this way, the fluid passing through the
evaporator may be suction by the compressor
in a complete gaseous condition.
DISMOUNTING
Drain the refrigerant circuit by means of the
charging station.
Dismount :
- attachment nut (
A
) of the connection
pipes;
- two attachment screws (
B
) of the
expansion valve (
C
) on evaporator.
REMOUNTING
When remounting, replace the pipes sealing
gaskets.
The required tightening moment for
B
screws is of
0,8 daNm
.
The required tightening moment for
A
pipes
attachment nut is of
0,57 daNm
Vacuum the unit then perform its filling with
refrigerant fluid by means of the charging
station.
REMARK:
Adjustments of the expansion valve
spring are to be performed only by the
manufacturer.
The expansion valve is not to be
repaired and not adjustable.
vnx.su
Summary of Contents for Solenza 2004
Page 45: ...ENGINE E7J 262 10 ENGINE ASSEMBLY 10 20 CYLINDERHEAD Dismounting Remounting vnx su...
Page 51: ...ENGINE E7J 262 10 ENGINE ASSEMBLY 10 26 CYLINDERSBLOCK Dismounting Remounting vnx su...
Page 60: ...ENGINE E7J 262 10 ENGINE ASSEMBLY 10 35 DISTRIBUTION Dismounting Remounting vnx su...
Page 201: ...19 19 14 COOLING EXHAUST TANK Assembl exhaust vnx su...
Page 212: ...19 19 25 COOLING EXHAUST TANK Engine suspension TIGHTENINGMOMENTS daNm vnx su...
Page 221: ...CV JH3 051 21 MECHANICAL GEARBOX 21 1 Sectional view vnx su...
Page 272: ...GENERAL 30 3 30 Tightening moments in daNm FRONTHALF AXLE Front axle 10 5 6 2 2 7 2 7 vnx su...
Page 273: ...GENERAL 30 4 30 Tightening moments daNm REARAXLE Rear axle 8 5 3 5 7 5 12 22 vnx su...
Page 274: ...GENERAL 30 5 30 Tightening moments daNm REARAXLE Rear axle 7 5 2 12 1 45 vnx su...
Page 318: ...33 REAR AXLES ELEMENTS 33 4 Rear suspension LONGITUDINALSECTION vnx su...
Page 378: ...40 GENERAL 40 4 1 3 2 4 Openings clearance vnx su...
Page 379: ...40 GENERAL 40 5 9 7 6 5 10 12 11 8 Openings clearance vnx su...
Page 380: ...40 GENERAL 40 6 Openings clearance 19 16a 18 17 16c 21 16d 13 14 vnx su...
Page 381: ...40 GENERAL 40 7 Openings clearance 25 23 24 22 vnx su...
Page 382: ...40 GENERAL 40 8 26 32 36 31 35 26a 33 Openings clearance vnx su...
Page 478: ...62 AIR CONDITIONING 62 4 Air conditioning unit operating diagram vnx su...
Page 607: ...83 INSTRUMENT PANEL 83 1 Instrument panel without RPM meter vnx su...
Page 608: ...INSTRUMENT PANEL 83 83 2 Instrument panel with RPM meter vnx su...
Page 708: ...89 ELECTRIC DIAGRAMS 89 12 Electric components location on the vehicle vnx su...
Page 709: ...89 ELECTRIC DIAGRAMS 89 13 FUNCTIONAL ELECTRICDIAGRAMS Functional electric diagrams vnx su...
Page 719: ...89 ELECTRIC DIAGRAMS 89 23 Wires functions in connectors and couplings vnx su...
Page 721: ...89 ELECTRIC DIAGRAMS 89 25 Wires functions in connectors and couplings vnx su...
Page 805: ...89 ELECTRIC DIAGRAMS 89 12 Electric components location on the vehicle vnx su...
Page 806: ...89 ELECTRIC DIAGRAMS 89 13 FUNCTIONAL ELECTRICDIAGRAMS Functional electric diagrams vnx su...
Page 816: ...89 ELECTRIC DIAGRAMS 89 23 Wires functions in connectors and couplings vnx su...
Page 818: ...89 ELECTRIC DIAGRAMS 89 25 Wires functions in connectors and couplings vnx su...