14-2
Display
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Parameter Settings
BTV04 Basic Settings
Pressing "Shift + F6" enters the parameter setting function of the BTV04.
Pressing F1 sets the serial interface parameters.
F2 Serial Port X2 (RS 485)
Baud Rate
9600 (19200)
Parity
off
Protocol
SIS Master
F3 Serial Port X3 (RS 232)
Address
3
Baud Rate
9600
Parity
off
Protocol
ASCII + SIS
Fig. 14-2: BTV04 Interface
PC->BTV04->DKC Push-Through Operation
It is possible to push the serial communication from the PC and DKC
through to the BTV04 via the second interface connection. For this type of
operation, hard-wiring of the interface between the BTV04 and the DKC
can remain intact. In such a case, no changes are required to the
interface settings, as long as the communication between the BTV04 and
the DKC is already functioning.
RelayMode.BMP
Fig. 14-3: Connection
Switching Between the User Interface and the Programming Displays
User Interface
Å
Programming Displays
SHIFT-HELP
Programming Displays
Å
User Interface
Press this key twice MAIN MENU