8-12
Functions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Pi5005fj_AE.WMF
Fig. 8-10: Distance-coded Measuring System Specified with Greater and Lesser
Distances
The greater distance is entered in C013, Distance-coded reference
offset 1, the lesser distance in C013, Distance-coded reference offset
2. The unit for these two distances is the grating period. Typical values for
a linear scale with distance-coded reference marks are 20.02 mm for the
greater distance and 20.00 mm for the lesser distance with a resolution of
0.02 mm. The numerical values 1001 or 1000 are then entered in
parameter C013.