15-12
EMD Module (EcoX-Bus)
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
15.5 Electrical Connection
Before You Begin
For operation, an input/output module must be supplied with power.
In addition, note the following:
CAUTION
Electrical components will be damaged by
electrostatic discharge!
⇒
When handling electrical components, ensure that you
and any equipment are appropriately grounded.
CAGE CLAMP
Connections
All connector clamps for supply lines as well as sensor and actor
connections are made with CAGE CLAMP connections.
The CAGE CLAMP
connections are appropriate for fine or single-
conductor wiring. Generally, only one conductor can be connected to
each clamp.
The CAGE
CLAMP
connection is structured so that, with proper
handling, a fine conductor can be fed through without splicing and can be
securely clamped. Under normal operating conditions, this direct
clamping, e.g. direct contact between the conductor and the clamp’s
busbar, achieves optimal contact quality.
Note:
If structural characteristics or ambient conditions require
splicing protection in the form of ferrules, the smaller
conductor diameter should be selected.
General Information