6-60
Writing the User Program
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
SET - Set Variable Value
or
Value
Operational Sign
Target Variable
Using this command, variables can be set from the program or copied
from another variable.
Valid inputs for ’Target Variable’ and the corresponding limit values:
Variable Type
Number
Minimum Value
Maximum Value
User-programmable
V600 to V999
-99999999.999999
+99999999.999999
Indicated Basis
V500 to V507
V510 to V517
+600
+999
Indicated Offset
Factor
V508, V518
+0
+399
Indicated Index
V509, V519
+0
+399
Fig. 6-29: Set Command: Valid Target Variable
Valid Inputs for ’Value’:
Variable Type
Value
Access
Comment
User-programmable
V600 to V999
Direct
Indicated Basis
V500 to V507
V510 to V517
Indicated
Indicated Offset Factor
V508, V518
Direct
Indicated Index
V509, V519
Direct
System
V000 to V199
Direct
Only variable, according
to Fig. 6-1 and Fig. 6-2
No Variable
Value
Fig. 6-30: Set Command: Valid Target Variable
See also Section 6.6 – Variables.
The program proceeds to the next instruction following the time period of
one cycle.
SET V600 = + V601
SET V600 = +12345678.123456
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......