9-4
Parameters
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Online Changeable Parameters
Changeable Parameters
•
A110
Bipolar Jerk Limiting Time Constant
•
AA15 ... AA18
Signal Controlbit 1 ... 4
•
B006 ... B008
Analog Output 2
•
CRxx
All Controller Parameters
Conditionally Changeable Parameters
Can be changed, if no SA1 command is active in the program:
•
B003 ... B005
Analog Output 1
Can be changed, if no program is running:
•
C019
SSI Encoder Reference Distance
The following parameters should only be changed at idle PLS encoder in
Manual Mode. Each modification will cause a dead time of 10ms in which
the outputs of the PLS stay unchanged.
•
N111 ... N118
Function of Output Channel 1
•
N121 ... N131
Switch 1
Input Unit
The input unit is defined in Parameter A101 Feed Constant. The feed
constant is defined as the linear displacement of the load during one
revolution of the gear output shaft. Input can be in any desired dimension
and is referred to below as the input unit (IU).
It is important that all other measurements entered be referenced to this
same unit.
e.g.
IU [mm]
In this case, the velocity is entered or shown as IU/s,
hence mm/s.
IU [inch]
In this case, the velocity in entered or shown as IU/s,
hence inches/s.
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......