Writing the User Program
6-13
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Variables
Definition
520
<V500> + <V508> * <V509>
521
<V501> + <V508> * <V509>
522
<V502> + <V508> * <V509>
523
<V503> + <V508> * <V509>
524
<V504> + <V508> * <V509>
525
<V505> + <V508> * <V509>
526
<V506> + <V508> * <V509>
527
<V507> + <V508> * <V509>
528
508
529
509
Fig. 6-7: Variable Block 1: Contents of the indexed variables with actual Offset
Factor V508 and actual Index V509
Variables
Definition
530
<V510> + <V518> * <V519>
531
<V511> + <V518> * <V519>
532
<V512> + <V518> * <V519>
533
<V513> + <V518> * <V519>
534
<V514> + <V518> * <V519>
535
<V515> + <V518> * <V519>
536
<V516> + <V518> * <V519>
537
<V517> + <V518> * <V519>
538
518
539
519
Fig. 6-8: Variable Block 2: Contents of the indexed variables with actual Offset
Factor V518 and actual Index V519
All NC commands using Variables V500-V507 or V510-V517, are
executed in their indexed form.
If access to a variable outside of the range V600 to V999 is made,
(besides system variables), the error message "F- 02 23 – Wrong
variable index" is issued.
If these variables are written via the serial interface, fieldbus or using the
SET command, they are written without an index (directly).
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......