12-4
Diagnostic Message Descriptions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
12.1 Error Diagnostics for Amplifier F. ..
F208 UL The motor type has changed
This message is displayed when the unit is powered up for the first time
with a new motor.
The regulator settings for the current, velocity and position loops are
stored in the feedback memory on the motor. After powering up, the
controller compares the motor type stored in the parameter with the
connected motor type. If the two do not match, the basic control loop
setting must also be adjusted.
With the Basic Load command, the default control loop settings are
loaded from the feedback memory into the drive controller. The previous
control loop settings are overwritten. The Basic Load command is started
by pressing the S1 key on the controller.
Causes:
The motor has been replaced.
A parameter file was loaded in which the motor type is different from the
motor type present.
Remedy:
Press the S1 key.
F209 PL Load parameter default values
After replacing the firmware version, the drive displays “PL” if the
parameters have been changed compared to the old firmware. Pressing
the S1 key on the controller clears all of the parameters and sets them
to the default values.
Cause:
The firmware has been replaced; the number of parameters in the new
firmware has changed compared to the old version.
Remedy:
Press the S1 key on the controller. All parameters will be cleared and
preset with the parameters assigned at the factory.
CAUTION
Following acknowledgement of the S1 key, a save query
is also issued. The parameters can then be saved via the
serial interface, or the function for presetting the
parameters can be suppressed.
F217 Blower not connected
For the 100A and 200A drive controllers, the blower must always be
connected.
Cause:
- Blower is not connected or is incorrectly connected
Remedy:
- Connect or replace blower
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......