15-4
EMD Module (EcoX-Bus)
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Outputs
Number
16
Connections
triple-conductor
External Power Supply
total
by group
with power supply clamps 24 V, 0 V
and ground clamp
with power supply clamps for each
group of 8 outputs
Rated Voltage
U
B
V [DC]
24
Rated Current
maximum per output
maximum per group
maximum per module (16 DO)
I
B
A
0.5
4.0
8.0
Leakage Current
mA
< 0.2
Maximum Switching Frequency
with Ohm load
with inductive load
Short-Circuit Diagnostic
no short-circuit diagnostic possible
Short-Circuit Protection
electronic, automatic re-start
Electronic Isolation – Circuit Side
no
Conditions for Use
Ambient Temperature Allowed
°C
0° ... +55°
Storage and Transport Temperature
°C
-25° ... +70°
max.
m over NN
2000
Max. Allowable Relative Humidity
%
10 - 45, no condensation
Air Pressure during Operation
hPa
86 ... 106
Protection Type
IP 20 according to EN 60529
/IEC 529
Special Requirements for Operation
The unit can be used in locations
where dust, caustic steam, caustic
gases or ionized radiation can be
present, only if additional measures
are undertaken!
Fig. 15-5: EMD Input/Output Module Data
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......