ECODRIVE03-FL*-04VRS
Writing the User Program
6-47
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
So that the motor is not overloaded, the torque values should be set by
the MOM command. The start of the positioning move generally occurs
150 ms after the command is loaded.
Note:
Before invoking commands PFA and PFI, the torque limit
values must be set by invoking the MOM command.
See also Section 8 function ’Movement to Positive Stop.’
Example:
0100
MOM
1 020 040 00.00.0 400
Torque Reduction:
To positive stop 20%
At positive stop 40%
0101
POA
1 000250.000 999
Initiate movement at maximum
speed.
0102
VCC
1 +000200 100 1 1
Wait until po200 with
v=10% is reached.
0103
PFA
1 +000300.000 100 002
Movement to positive stop until
po300 is reached.
0104
JMP
0200
Jump if positive stop was not
recognized.
0105
BCE
0120 I0.00.7 1
Positive stop was recognized.
Jump if input is 1.
0106
JMP
0105
Wait until input becomes 1.
0120
PSA
1 +000000.000 999
Return to po0
0121
JST
0100
Jump with stop according to
instruction 0100 (wait for next
cycle)
0200
AEA
Q0.01.2 1
Set output.
0201
PSA
1 +000000.000 999
Return to po0
0202
JST
0000
Jump with stop according to
instruction 0000.
Fig. 6-22: PFA Command Program Example
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......