9-28
Parameters
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
AA15 Signal Control Bit 1
AA15 Signal Control Bit 2
AA15 Signal Control Bit 3
AA15 Signal Control Bit 4
M2.02.2 M2.02.3 00
Signal change test assignment
can be edited on-line via RS
Input Bit : Signal to be tested
M0 – M5; M8 ; I0 – I4 ; Q0 – Q3
Input Bit : Test Range
(00.00.0 Function deactivated)
M0 – M5; M8 ; I0 – I4 ; Q0 – Q3
Assignment: Signal Change Test:
00 = No test is done.
01 = Test for signal level 0
when not enabled, tests for a change in the leading edge
The input must be at '0' during the entire test range
02 = Test for signal level 1
when not enabled, tests for a change in the leading edge
The input must be at '1' during the entire test range
03 = Test for rising edge within the test range
04 = Test for falling edge within the test range
05 = Test for signal level 0 when leaving the test range
06 = Test for signal level 1 when leaving the test range
07 = Test for a rising edge within the test range.
08 = Test for a falling edge within the test range.
Note:
Parameters AA15 to AA18 are also writable in Manual and
Automatic Modes!