12.9 NC- Status Diagnostics A- .. ..
A- 0007 Stop is active
No voltage at the Stop input X210/4 or the automatic program was
stopped using a Stop command (JST).
A- 0008 Manual vector program is active
The Manual Vector program in Parameter AA01 is currently being
processed.
A- 0009 Function interrupt is active
24V not present at input programmed in Parameter A116.
A- 0011 Feed rolls open
In Parameters AA05 and AA06, the function ’Open feed rolls’ was
activated and the output for opening the feed rolls is currently active,
based on the PLS position or the input state.
A- 0012 Press Timeout
In Parameter AA19, press monitoring is active. No signal change for the
feed area (Parameter A116) occurred during the set time (Parameter
AA19).
A- 0013 Waiting for Feed Angle
The signal at input ’Feed angle monitoring’ (feed angle) is not present.
See Parameter A116.
A- 0026 Control signal bit 1 invalid
The function was activated in Parameters AA14 and AA15, to compare
PLS positions with a particular state of an input signal. The state of the
input signal from Parameter AA15 did not correspond to the PLS position.
Check input signal and PLSs.
A- 0027 Control signal bit 2 invalid
The function was activated in Parameters AA14 and AA16, to compare
PLS positions with a particular state of an input signal. The state of the
input signal from Parameter AA16 did not correspond to the PLS position.
Check input signal and PLSs.
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......