14-20
Display
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Data Display
Display Variable
The contents of the programmed variable are written to the display
cyclically.
The contents of all variables can be displayed.
The number of places before and after the decimal can be designated.
N0500 TXT 0 1-0-2-00-100-183
Display of the Actual Position with Places Before the Decimal
Parameter
Description
min.
max.
1
Assignment: Displays
--
--
0
0 = Display Variable
--
--
2
Display Line
1
6(7)
00
Display Position
00
21
100
Variable Number
000
999
--
--
0 = Without operational sign
1 = With operational sign
0
1
Number of Places Before Decimal
1
8
183
1xx
x8x
xx3
Number of Places After Decimal
0
6
Fig. 14-8: Variable Display
Display: Actual Position
TXT
0
1-0-3-08-100-183
V100 = Actual Value, Axis1
Display Markers
N0500 TXT 0 1-1-2-00-M2.00.0
Parameter
Description
min.
max.
1
Assignment: Displays
--
--
1
Display Marker Bit
--
--
2
Line
1
6(7)
00
Position
00
21
M2.02.0
Complete Identifier
M = Marker
I = Input
Q = Output
000
999
Fig. 14-9: Marker Display
Summary of Contents for Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Page 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Page 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Page 489: ......