Description
Symbol
Unit
KMS03.1B-A036-P-D7-ET-
END-NN-NN-FW
KMS03.1B-B036-P-D7-ET-
END-NN-NN-FW
Rise of voltage at output with
U
LN_nenn
and 7.5 m motor cable
length phase-phase (10‑90%)
6)
dv/dt
kV/µs
5.00
Rise of voltage at output with
U
LN_nenn
and 7.5 m motor cable
length phase-ground (10‑90%)
7)
dv/dt
kV/µs
5.00
Output frequency range when
f
s
= 4 kHz
f
out_4k
Hz
0 … 400
Output frequency range when
f
s
= 8 kHz
f
out_8k
Hz
0 … 800
Output frequency threshold to
detect motor standstill
8)
f
out_still
Hz
0...4
Maximum output current when
f
s
= 4 kHz
I
out_max4
A
36.0
Maximum output current when
f
s
= 8 kHz
I
out_max8
A
28.2
Continuous output current when
f
s
= 4 kHz
I
out_cont4
A
12.0
22.0
Continuous output current when
f
s
= 8 kHz
I
out_cont8
A
8.8
22.0
Continuous output current when
f
s
= 4 kHz; output frequency
f
out
less than f
out_still
I
out_cont0Hz
_4
A
12.0
22.0
Continuous output current when
f
s
= 8 kHz; output frequency
f
out
less than f
out_still
I
out_cont0Hz
_8
A
5.9
16.0
Latest amendment: 2018-02-22*
1)
Observe supply voltage for motor holding brake
2)
See information on "Rated power consumption control voltage
input at U
N3
"
3)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
4)
Also depending on firmware and control section; see parame‐
ter description "P‑0‑0001, Switching frequency of the power
output stage"; see "P-0-4058, Amplifier type data"; for supply
units the switching frequency is 4.2 kHz
5)
Plus dissipation of braking resistor and control section
6) 7)
Guide value, see following note
8)
See following note regarding output current reduction
Tab. 5-18:
KMS - Technical data
Rated power consumption control voltage input at U
N3
Plus motor holding brake, plus power consumption of externally
connected inputs/outputs, plus safety option
110/407
Technical data of the components
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04