6.6.7
XD1, mains voltage
View
Connection Function
L1
Connection to mains filter (XD1.2.L1)
L2
Connection to mains filter (XD1.2.L2)
L3
Connection to mains filter (XD1.2.L3)
Equipment grounding conductor
Tab. 6-55:
Pin assignment
Mechanical data
Screw terminal (connector)
Unit
max.
Connection cable
Stranded wire
mm
2
6
AWG
8
Stripped length
mm
10
Tightening torque
Nm
0.8
Tab. 6-56:
Mechanical data
Electrical data
Screw terminal (connector)
Unit
Value
Occurring current load and minimum required
connection cross section
A
See technical data (I
L_cont
, I
L_max
and A
LN
)
Occurring voltage load
V
See technical data (U
LN
)
Tab. 6-57:
Electrical data
Cables
Description
Value
Order type
Maximum allowed length
1 m
Tab. 6-58:
Cables
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
201/407
Connection points