Connecting the cables
1. Take off connection cover and remove protective covering
2. Put motor power cable connector (
) through big opening and
plug connector (XD3, XG3) into device.
(
additionally contains the connector for digital motor encoders
(XG4). With RHS0725 it is not required to connect the separate encoder
cable and the
dummy cover is put on the connection
cover.)
3. Screw on cable plate at connection cover with 2.5 Nm.
4. Put encoder cable connector (
) through small opening and
plug connector (XG4, XG8) into device.
5. Screw on cable plate at connection cover with 2.5 Nm.
6. Screw on connection cover with 2.5 Nm.
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
189/407
Connection points
R911335703_Edition 04 Bosch Rexroth AG