Description
Symbol
Unit
Value
Maximum concentration of corrosive gases
According to degree of protection
Vibration sine: axial
acceleration at 10 … 2000 Hz
1)
-
g
1
Vibration sine: radial
acceleration at 10 … 2000 Hz
1)
-
g
1
With
3
Overvoltage category
-
-
III (according to IEC 60664-1)
1)
According to EN 60068-2-6
2)
Reduced performance data for drive controllers: allowed DC
bus continuous power, braking resistor continuous power, con‐
tinuous current
3)
Reduced performance data for motors: performance, torque S1
and S3
Tab. 4-9:
Ambient and operating conditions (KSM)
Ambient and operating conditions (KMS, KMV, KNK, KLC)
Description
Symbol
Unit
Value
Degree of protection (IEC 60529)
-
-
IP65
Use within scope of CSA / UL
-
-
For use in NFPA 79 Applications only!
Temperature during storage
-
-
See
chapter 4.2.2 "Storing the components" on
Temperature during transport
-
-
chapter 4.2.1 "Transporting the components" on
Allowed mounting position
Definition of mounting positions: See
"Mounting positions of components" on page
-
-
KMS
G1, G2, G3, G4, G5
(KMS03.1B-A: reduced
performance with G2, G4, G5)
KMV, KNK, KLC
Cooling types B and I: G1, G2,
G3, G4
Cooling types A and W: G1
Installation altitude
h
nenn
m
1000
Ambient temperature range
T
a_work
°C
0 … 40
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
53/407
General data and specifications
R911335703_Edition 04 Bosch Rexroth AG