6.7.4
XD1.2, supply unit
View
Connection Function
L1
Connection to supply unit
L2
Connection to supply unit
L3
Connection to supply unit
Equipment grounding conductor
Tab. 6-76:
Pin assignment
Mechanical data
Screw terminal (connector)
Unit
max.
Connection cable
Stranded wire
mm
2
6
AWG
8
Stripped length
mm
10
Tightening torque
Nm
0.8
Tab. 6-77:
Mechanical data
Electrical data
Screw terminal (connector)
Unit
Value
Occurring current load and minimum required
connection cross section
A
See technical data (I
L_cont
, I
L_max
and A
LN
)
Occurring voltage load
V
See technical data (U
LN
)
Tab. 6-78:
Electrical data
Cables
Description
Value
Order type
Maximum allowed length
1 m
Tab. 6-79:
Cables
6.7.5
XD13, fan power supply
Connection point for RKB0054 cable.
See
chapter 10.17 "RKB0054, fan cable" on page 330
.
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
209/407
Connection points
R911335703_Edition 04 Bosch Rexroth AG