Technical design
Type of construction of motor
Type of construction of motor B5 according to EN 60034-7
Housing varnish
Black, RAL 9005
Vibration severity level (vibration
quality)
A, according to EN 60034-14: 2004
Concentricity, run-out and align‐
ment
According to DIN 42955, ed. 12.81 (IEC 60072-1)
Encoder
Concentricity tolerance
Run-out and alignment tolerance
S1, S3, M1, M3
N
---
N
---
Tab. 5-4:
Tolerance for concentricity, run-out and alignment, depending on en‐
coder option
Flange
According to DIN 42948, ed. 11.65
Output shaft, shaft end and cen‐
tering hole
Motors with keyway have been balanced with the complete key. The machine
element to be driven has to be balanced without a key.
Shaft end cylindrical, acc. to DIN 748 Teil 3, ed. 07.75 (IEC 60072-1)
Centering hole, according to DIN 332 Teil 2, ed. 05.83
Type
Corresponding key,
according to DIN 6885-A
(is not part of the scope of
supply of the motors)
Centering hole, according
to DIN 332 part 2,
ed. 05.83
KSM02.1B-041
5 × 5 × 20
DS M5
KSM02.1B-061
6 × 6 × 32
DS M6
KSM02.1B-071
10 × 8 × 45
DS M10
KSM02.1B-076
8 × 7 × 40
DS M8
Tab. 5-5:
Key and centering hole
78/407
Technical data of the components
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04