5.7
KNK03 mains filter
5.7.1
KNK03 data sheet
Technical data - currents, voltages, power
Description
Symbol
Unit
KNK03.1A-
NR-A0008-P-
U226-A4-
NNNN
KNK03.1A-
NR-B0012-P-
U226-A4-
NNNN
KNK03.1A-
NR-I0002-P-
U226-A4-
NNNN
KNK03.1A-
NR-W0010-P-
U226-A4-
NNNN
Degree of protection according to
IEC 60529
IP
IP65
Listing in accordance with UL
standard
UL 61800-5-1
Listing in accordance with CSA
standard
CSA C22.2 No. 274-13
Mass
m
kg
24.00
20.00
24.00
Three-phase mains voltage at TN-
S, TN-C, TT mains
U
LN
V
AC 380…500
Mains voltage, three-phase at IT
mains
2)
U
LN
V
AC 380…500
Mains voltage, three-phase at
Corner-grounded-Delta mains
U
LN
V
Not allowed
Tolerance rated input voltage U
LN
%
±10
Mains input contin. current
I
L_cont
A
8.1
12
2.3
9.5
Typical inductance per winding at
I
cont
L
typ
µH
2.3
Power dissipation at continuous
current and continuous DC bus
power respectively
3)
P
Diss_cont
W
147
175
104
160
Allowed leakage capacitance
C
Abl
nF
226
Allowed Y-capacitance
C
Y
nF
2200
Insulation resistance at 500 V DC
R
is
Mohm
> 1
Required wire size in accordance
with NFPA 79 and UL 508 A
(internal wiring);
4)
A
LN
AWG
14
Latest amendment: 2019-08-08*
1) 2)
Mains voltage > U
LN
: Use a transformer with grounded neutral
point, do not use autotransformers!
3)
Plus dissipation of braking resistor and control section
4)
Copper wire; PVC-insulation (conductor temperature 90 °C;
T
a
≤ 40 °C) in accordance with NFPA 79 chapter 12 and
UL 508A chapter 28
Tab. 5-17:
KNK - Technical data - currents, voltages, power
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
105/407
Technical data of the components
R911335703_Edition 04 Bosch Rexroth AG