![BENSHAW RediStart MX3 Series User Manual Download Page 63](http://html1.mh-extra.com/html/benshaw/redistart-mx3-series/redistart-mx3-series_user-manual_2735259063.webp)
Description of the Keys on the Remote LCD Keypad
4.3
Description of the Keys on the Remote LCD Keypad
55
4 - KEYPAD OPERATION
Key
Function
•
This key causes the starter to begin the start sequence. The direction is dependent on wiring and phase
selection.
•
In order for this key to work, the Local Source (QST04) parameter must be set to "Keypad".
•
Increase the value of a numeric parameter.
•
Select the next value of an enumerated parameter.
•
It scrolls forward through a list of parameters within a group (when the last parameter is displayed, it
scrolls to the beginning of the list).
•
When a list of faults is displayed, it moves from one fault to the next.
•
When a list of events is displayed, it moves from one event to the next.
•
When the starter is in the Operate Mode, pressing [UP] allows you to change which group of meter
values is monitored.
•
Decrease the value of a numeric parameter.
•
Select the previous value of an enumerated parameter.
•
It scrolls backward through a list of parameters within a group (when the first parameter is displayed,
it scrolls to the end of the list).
•
When a list of faults is displayed, it moves from one fault to the previous fault.
•
When a list of events is displayed, it moves from one event to the previous event.
•
When the starter is in the Operate Mode, pressing [Down] allows you to change which group of meter
values is monitored.
•
When editing a numeric parameter, the [LEFT] arrow key moves the cursor one digit to the left. If
cursor is already at the most significant digit, it returns to the least significant digit on the right.
•
When in Menu mode, the [LEFT] arrow allows groups to be scrolled through in the opposite direction
of the [MENU] Key.
•
Stores the change of a value.
•
When in Fault History, [ENTER] key scrolls through information logged when a fault occurred.
•
When in Event History, [ENTER] key scrolls through information logged when an event occurred.
•
When an alarm condition exists, [ENTER] scrolls through all active alarms.
•
[MENU] scrolls between the operate screen and the available parameter groups.
•
When viewing a parameter, pressing [MENU] jumps to the top of the menu.
•
When a parameter is being edited and [MENU] is pressed, the change is aborted and the parameter’s
old value is displayed.
•
The [STOP/RESET] key halts the operation of the starter (Stop Key).
•
If a fault has occurred, the [STOP] key is used to clear the fault (Reset Key).
•
The [STOP/RESET] key always halts the operation of the starter if the control source is set to
"Keypad". If the control source (QST 04/QST 05) is not set to "Keypad", [STOP] key may be
disabled using the Keypad Stop Disable (I/O26) parameter.
Table 19: Function of the Keys on the LCD Keypad
start
enter
menu
stop
reset
Summary of Contents for RediStart MX3 Series
Page 9: ...1 Introduction 1...
Page 15: ...2 Technical Specifications 7...
Page 35: ...3 Installation 27...
Page 61: ...4 Keypad Operation 53...
Page 71: ...5 Parameter Groups 63...
Page 79: ...6 Parameter Description 71...
Page 145: ...7 Theory of Operation 137...
Page 188: ...NOTES 180 7 THEORY OF OPERATION...
Page 189: ...8 Troubleshooting Maintenance 181...
Page 208: ...NOTES 200 8 TROUBLESHOOTING MAINTENANCE...
Page 209: ...Appendices 201...