7.11.1
Phase Controller:
Phase control can be used to directly control the voltage applied to motors, resistive heaters, etc. When in Phase Control mode, the phase
angle of the SCRs, and hence the voltage applied, is directly controlled based on the analog input signal. The MX
3
reference command
can be generated from any 0-10V, 0-20mA or similar source, such as a potentiometer, another MX
3
or an external controller such as a
PLC.
7.11.2
Master/Slave Starter Configuration:
In the master / slave configuration, one "master" starter can directly control the output of one or more "slave" starters. To utilize the
master / slave configuration, one starter needs to be defined as the "master" starter. The Starter Type parameter of the "master" starter
should be configured appropriately as a Soft Starter (normal or ID), Phase Controller or Current Follower. If configured as a soft starter,
the acceleration and deceleration profiles need to be configured for proper operation.
To configure a master / slave application:
1.
The analog output of the master MX
3
control card needs to be connected to the analog input(s) of the slave card(s).
2.
The master MX
3
analog output needs to be configured. Set the Analog Output Function parameter to option 10 or "0 - 100% firing".
The Analog Output Span parameter should be set to provide a 0-10V or 0-20 milliamp output to the slave starter(s). Adjust analog
output jumper (JP1) to provide either a voltage or a current output. Set the slave MX
3
Starter Type parameter to Phase Control and
verify that the Analog Input Offset and Analog Input Span parameters are set to accept the master signal.
3.
The slave MX
3
needs to be provided with a start command from the master MX
3
. A RUN programmed relay from the master MX
3
can
be used to provide the start command to the slaves. The slave(s) Control Source parameters (Local Source and Remote Source)
settings need to be set appropriately.
4.
The slave MX
3
analog input(s) needs to be configured for the appropriate voltage or current input signal type. Set the analog input
jumper (SWI-1) to the desired input type.
For additional master/slave application information, consult the factory.
174
7 - THEORY OF OPERATION
Summary of Contents for RediStart MX3 Series
Page 9: ...1 Introduction 1...
Page 15: ...2 Technical Specifications 7...
Page 35: ...3 Installation 27...
Page 61: ...4 Keypad Operation 53...
Page 71: ...5 Parameter Groups 63...
Page 79: ...6 Parameter Description 71...
Page 145: ...7 Theory of Operation 137...
Page 188: ...NOTES 180 7 THEORY OF OPERATION...
Page 189: ...8 Troubleshooting Maintenance 181...
Page 208: ...NOTES 200 8 TROUBLESHOOTING MAINTENANCE...
Page 209: ...Appendices 201...
Page 237: ...Publication History Revision Date ECO 00 12 15 06 Initial Release...