BVS ID-M1280xF1-xx-xxx
english
49
•
•
•
•
•
•
Value
(dez)
Value
(hex)
Bit
Name
Description
Reset to binary "0"
32
20 00
5
Ready
This bit signals that
BVS ID
is currently
ready. It is reset while
BVS ID
performs an
administrative task that prevents it from
processing commands. The bit is
particularly reset
during the startup of
BVS ID
including
the load of the inspection,
during the change of an inspection
program by means of the web interface
or the TCP/UDP communication
interface,
while the user resides in the
configuration mode,
during Auto Setup,
if the File Device is selected as Image
source in the Inputs tab of the
configuration mode page, or
the System error is set.
BVS ID
is not considered to be busy
during the execution of an inspection, and
the
Ready
bit will be set. For sequence
control during an inspection run, the bit
Waiting For Trigger
is provided.
Automatically, as
soon as the
BVS ID
performs an
administrative task.
256
00 01
8
Trigger
Overflow
This bit signals that a trigger has been
received while
BVS ID
was not waiting for
a trigger, i.e. while the bit
Waiting For
Trigger
was binary "0". The behaviour upon
such an unexpected trigger is undefined:
the trigger might cause an image
acquisition or it might not.
By the user with the
command
Reset
errors
(0x16) and
automatically during
change to
configuration mode.
1024
00 04
10
Report
Error
This bit becomes active as soon as a
report file could not be transferred and got
lost.
By the user with the
command
Reset
errors
(0x16) and
automatically during
change to
configuration mode.
4096
00 10
12
Input Data
Error
It is set for input container overflow (more
input containers than inspection results, so
that one input container was discarded or if
received reference value is too large at the
time of execution of tool
"Inputs"
) or
underflow (more inspection results than
input containers, so that one input
container was used multiple times or if the
received reference value is too small at the
time of execution of tool
"Inputs"
).
By the user with the
command
Reset
errors
(0x16) and
automatically during
change to
configuration mode.
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...