BVS ID-M1280xF1-xx-xxx
160
english
Name
Inde
x
Subin
dex
Acc
ess
Leng
ht
Data
Type
Data
Storag
e
Default
Process Data
Output Descriptor
0x00
0F
(15)
0
R
96
byte
s
UINT8[ ]
n/a
-
PD Description
This parameter is used to specify the structure of the currently selected process data profile for input and output
data. The individual process data variables are described.
The total list is possible via subindex 0, a single entry is possible using a specific subindex. Subindex 1
corresponds to the least significant (or the element most recently transferred in the process data stream). When
reading out the entire list, this element is transferred first.
The length of the list is dependent on which process data profile is selected. A single element has a length of 3
bytes.
Byte number
Contents
Values
Byte 1
Data type
0: OctetStringT
1: Set of BoolT
2: UIntegerT
4: Float32T
5…255: reserved
Byte 2
TypeLength
0…255 bits
Byte 3
Bit offset
0…255 bits
Events
With special process data values, the
BVS ID
automatically checks whether the values are updated in the time
period specified by the
BVS ID
. If an update timeout is triggered as a result, this is output via the following
diagnosis messages:
Event
Code
Event Type
Event – Description – Remedy
Device Status
0x1851
(6225)
Notification
Process Data Update Timeout – for information
purposes only
0 – Device is operating
properly.
0x1852
(6226)
Warning
Multiple Process Data Update Timeout – for
information purposes only
0 – Device is operating
properly.
If the variant of the
BVS ID
is changed, the currently set profile is retained.
In the case that the corresponding PD profile is not valid for this variant, the default profile for the corresponding
variant is selected.
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...