BVS ID-M1280xF1-xx-xxx
142
english
•
•
•
•
•
•
1.
2.
Event
Code
Event Type
Event – Description – Remedy
Device Status
0x8D10
(36112)
Warning
Device Temperature Upper Warning – The set
upper temperature warning threshold has been
exceeded.
0 – Device is operating
properly.
0x8D20
(36128)
Warning
Device Temperature Lower Warning – The set
lower temperature warning threshold is below the
minimum value..
0 – Device is operating
properly.
Variant Dependence
The functionality is available in all variants.
Inclination and Installation Aid
Description
This feature offers two functions:
Inclination detection
Installation and alignment aid
The inclination aid detects a deviation in the inclination compared to a reference position. The reference position
can be freely selected and taught in.
The internal position sensor follows the vertical earth axis. Angular deviations to this axis can be recognized,
parallel shifts to the axis or rotation around this axis cannot.
Measurement data for inclination detection:
Measurement range: 0…180°
Resolution: 1°
Accuracy: +/−1°
Measurement period: 1000 ms (data refresh rate = 1 second)
With the inclination detection it can be recognized whether the
BVS ID
has changed its original installation
position and therefore a possible misalignment and resulting malfunctions can be detected at an early stage.
The configuration can be performed via ISDU parameters.
Using the feature
Switch on, establish IO-Link communication.
Send system command 0xC0.
→
The inclination measurement data is available via ISDU (e.g., 0x2154) or via the process data.
Recognizable adjustments
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...