BVS ID-M1280xF1-xx-xxx
156
english
Command Value
Device Action
0x81 (129)
Application Reset – This reset is performed using IO-Link specification V1.1.2.
– Resets all parameters and device settings to default values (with the exception of
the
identification and tagging parameters)
– No reset of the configuration of the device variant
– Set DS-upload request (accept the data in the memory)
– No communication stop or restart
0x82 (130)
Reset Factory Settings – This reset is performed using IO-Link specification V1.1.2.
– Reset all parameters and device settings to default settings (including
identification and
tagging parameters)
– Reset the configuration of the device variants to the default variant
– No DS-upload request
– No communication stop or restart
0xA5 (165)
Maintenance Reset – Resets all resettable maintenance and service life parameters
for the user so that the next maintenance cycle can begin
Variant Configuration
ISDU
Name
Inde
x
Subin
dex
Acc
ess
Leng
ht
Data
Type
Data
Storag
e
Default
Device Variant
0x0
055
(85)
0
R/
W
2
byte
s
UINT16(
ENUM)
No
1 (Default)
Device Variant
This parameter indicates which variant is currently set. The device variant can be changed either with this
parameter or by using the IO-Link compatibility mode. If this parameter is written, the device variant is not
changed immediately but instead after the
BVS ID
is restarted. If the
device variant is changed via the IO-Link compatibility mode, the change in this parameter is visible immediately.
This parameter is not changed by a reset.
The following device variants are available::
1.
2.
After a variant changeover, an inconsistent configuration may occur because there is no automatic
changeover of parameters.
It is therefore recommended that the setup be done in the following order:
Variant setting
Perform factory reset or set valid parameters.
NOTE
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...