BVS ID-M1280xF1-xx-xxx
english
135
The output of the current boot cycle can serve as a control for the service interval as well as for preventative
maintenance. Schedules for regular maintenance can be tied to the values of the Boot Cycle Counter.
Process Data
Object ID
Name
Description
Direction
0x001E (30)
Boot Cycle Counter
Output of the current Boot Cycle Counter
Input
0x001F (31)
Custom Boot Cycle
Counter
Output of the resettable Boot Cycle Counter
Input
ISDU
Name
Inde
x
Subin
dex
Acc
ess
Leng
ht
Data
Type
Data
Storag
e
Default
Boot Cycle
Counter
0x00
58
(88)
0
R
8
byte
s
n/a
Boot Cycle
Counter
1
R
4
byte
s
UINT32
n/a
-
Custom Boot
Cycle Counter
2
R
4
byte
s
UINT32
n/a
-
Boot Cycle Counter
This parameter saves the value of the current boot cycle, which is incremented on each start.
Custom Boot Cycle Counter
This parameter saves the value of the current, user-defined counter, which is incremented on each start and
can be
reset via the Maintenance Reset system command.
System Commands
Command Value
Device Action
0x81 (129)
Application Reset – Resets the Custom Boot Cycle Counter with ISDU-index 0x58
subindex 2 to the default value 0.
0x82 (130)
Reset Factory Settings – Resets the Custom Boot Cycle Counter with ISDU-index
0x58 subindex 2 to the default value 0.
The maximum counter value that can be saved is 1,000,000 and, with a switch-on and switch-off every
12 minutes, this means a service life of over 20 years.
NOTE
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...