BVS ID-M1280xF1-xx-xxx
148
english
•
•
•
•
•
•
Process Data
Object ID
Name
Description
Directio
n
0x004A (74)
Vibration Level
Vibration level
Input
0x004B (75)
Vibration Alarm Status
Vibration alarm status
Input
The unit for Vibration Level is [mm/s].
The vibration alarm status flag is without units.
ISDU
Name
Inde
x
Subin
dex
Acc
ess
Leng
ht
Data
Type
Data
Storag
e
Default
Vibration Level
0x2
10E
(846
2)
0
R
4
byte
s
FLOAT3
2
n/a
-
Vibration Alarm
Configuration
0x2
10F
(846
3)
0
R/
W
5
byte
s
Yes
Vibration Alarm
Enable
1
R/
W
1
byte
BOOL
No
0
Vibration Alarm
Threshold
2
R/
W
4
byte
s
FLOAT3
2
No
0.0
Vibration Alarm
Status
0x2
110
(846
4)
0
R
1
byte
BOOL
n/a
-
Vibration Level
Vibration level, primarily the calculated v-RMS value (root mean square)
Unit: [mm/s]
Minimum value: 0,0
Maximum value: 1770,0
Vibration Alarm Enable
If the parameter is set (TRUE), the vibration level is compared with the vibration alarm threshold value. If the
vibration exceeds the threshold value, an event is created and sent.
0 = alarm deactivated
1…255 = alarm activated
Default = 0
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...