Length in bytes
Structure
Value
Description
2
UINT16
04
hex
User data length in bytes
2
UINT16
Result code
2
UINT16
The currently set Inspection ID
Result code type
Result code
Description
OK
00
hex
The inspection program change has been successfully
completed.
NOK Busy
16
hex
The application is currently in a mode in which requests can
not be processed (ready status is curently false).
NOK Inspection Error
1A
hex
An error occured while loading the inspection program due to
one of the following reasons:
Changing to an inspection program with ID 0 is not
possible via communication interfaces.
The inspection program with the given ID does not exist.
The maximum amount of inspection programs has been
exceeded, a change is permitted until inspection programs
are being deleted.
The inspection program is corrupt or the application ran
out of memory during load.
Example 1 (successful change):
A request to change to the existing inspection with the existing ID 5.
Message from the client to
BVS ID
: 31 00 02 00 05 00
BVS ID
responds to it with: 31 00 04 00 00 00 05 00
The bytes "00 00" indicate that the inspection change was successful.
Example 2 (failed change):
A request to change to the
non-existing
inspection with the ID 7.
Message from the client to
BVS ID
: 31 00 02 00 07 00
BVS ID
responds to it with: 31 00 04 00 1A 00 01 00
The bytes (1A 00) indicate that the change was not successful. The active inspection program is contained in
the last two bytes: (01 00), representing the active Inspection ID of 1.
For information about the reason of a failed Set Inspection ID request, the user is referred to the system
logs which can be viewed by means of the System Settings, tab System, of the Webinterface.
NOTE
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...