Current Operating Hours
This parameter saves the value of the operating hours since the last commissioning in seconds.
Total Operating Hours
This parameter saves the value of the operating hours since the first commissioning in seconds.
Custom Operating Hours
This parameter saves the value of the operating hours since the last reset in seconds.
Operating Hours Saving Mode
The current storage behavior can be set..
Value
Meaning
Description
0x00 (0)
Dynamic
The first save operation is performed 1 minute after switching on; the storage
interval than doubles after every save operation. This is limited to a storage
interval of 12 minutes. The intervals are 1, 2, 4, 8, 12 minutes.
0x01 (1)
Static
Operating hours counters are stored every 12 minutes.
System Commands
Command Value
Device Action
0x81 (129)
Application Reset – Resets Custom Operating Hours to the default value.
0x82 (130)
Reset Factory Settings – Resets Custom Operating Hours and Operating Hours
Saving Mode to the default value.
0xA5 (165)
Maintenance Reset – Resets Custom Operating Hours to the default value.
Boot Cycle Counter
Description
After each start, the current Boot Cycle Counter is read from the non-volatile memory, incremented by 1 and
rewritten. In addition, a second Boot Cycle Counter is implemented that can be reset.
The maximum counter value that can be saved is 1,000,000 and, with a switch-on and switch-off every
12 minutes (with static counter), this means a service life of over 20 years. If switched on and off more
frequently or in the case of dynamic storage, the maximum storage time is reduced depending on the
application.
NOTE
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...