BVS ID-M1280xF1-xx-xxx
english
47
The response to an action message contains a result code that informs about the success of the request. This
result code is contained in the first word of the user data. The result code can have the following values:
Name
Stat
e
cod
e
Meaning
OK
00
hex
Command was successfully executed.
OK
Inspection
ID
02
hex
Response to the command "Get inspection ID"; transfer of the
inspection
ID.
OK Date
Time
06
hex
Response to the command "Get date and time"; transfer of timestamp.
NOK Error
10
hex
An error occurred during the last transfer or execution of a command. A malformed
command (e.g. wrong length) is a possible reason.
NOK Invalid
Command
13
hex
An invalid command code was transferred.
NOK Busy
16
hex
Command could not be executed since the status Ready is not set. Possible reasons
for the Ready not to be set are listed in the section
Status message
.
NOK
Inspection
Error
1A
hex
The inspection program could not be changed. Possible reasons for the inspection
program change to fail are listed in the section
Set inspection ID
.
It is not guaranteed that an interrupted network connection via TCP is detected promptly. For this
reason, a watchdog functionality is recommended, which checks the connection in a defined time
interval. For this, you can request the status message. You can also use "Get Inspection ID", which
responds with the ID of the current inspection.
NOTE
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...