Vibration Alarm Threshold
Threshold value of the vibration for triggering an event. The comparison is performed for each axis and variable
with logical OR-link.
The hysteresis is fixed and is based on time (not on amplitude). If the vibration value exceeds the threshold value
for 50 ms, the alarm is activated.
Objective: debouncing and avoidance of shock values.
Unit: [mm/s]
Minimum value: 0,0
Maximum value: 1770,0
Vibration Alarm Status
The status flag is TRUE if the vibration exceeds the alarm threshold value.
0 = no alarm
255 = alarm
Events
Event
Code
Event Type
Event – Description – Remedy
Device Status
0x8CD1
(36049)
Warning
Vibration alarm
→
Check machine.
0 – Device is operating
properly.
This event indicates that the measured vibration value (v-RMS) exceeds the specified threshold value. The
machine should be inspected, since the vibration value is above the normal value. The status of the
BVS ID
itself is OK, it is functioning properly.
The higher vibration is caused outside of the
BVS ID
. The primary goal is the detection of trends, changes to
the vibration alarm value (see figure above yellow line).
Humidity
Description
The function monitors the air humidity in the
BVS ID
and informs of changes through corresponding IO-Link
events. The humidity detection returns an immediate reaction in the event of a critical failure. This reaction is
triggered if the humidity rises above a fixed threshold value and gives the clear if a satisfactory humidity value is
again achieved. The status when the level is exceeded the first time is stored permanently.
Process Data
Object ID
Name
Description
Directio
n
0x0023 (35)
Humidity Bad
Output of the current humidity evaluation; FALSE
means a humidity below above the threshold value,
TRUE means a humidity value equal to or above
the threshold value.
Input
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Konfigurationsanleitung english Configuration Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Konfigurationsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 79: ...BVS ID M1280xF1 xx xxx deutsch 77 Ablaufdiagramm Handshake...
Page 81: ...BVS ID M1280xF1 xx xxx deutsch 79 Ablaufdiagramm Handshake mit Input Toggle...
Page 83: ...BVS ID M1280xF1 xx xxx deutsch 81 Ablaufdiagramm Handshake mit Output Toggle...
Page 173: ...956115_AA DE K22 nderungen vorbehalten...
Page 174: ......
Page 175: ...english Configuration Guide BVS ID M1280xF1 xx xxx...
Page 176: ...www balluff com...
Page 245: ...BVS ID M1280xF1 xx xxx english 71 Handshake flow chart...
Page 247: ...BVS ID M1280xF1 xx xxx english 73 Handshake flow chart with input toggle...
Page 249: ...BVS ID M1280xF1 xx xxx english 75 Handshake flow chart with output toggle...