C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
335
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
I
NTERFACE
C
OMMANDS
SHOW
INTERFACE
Figure 8-1:
Example output from the
show interface
command
To display configuration and status information for interface
lo
, use the
command:
awplus#
show interface lo
awplus#show interface
Interface port1.0.1
Scope: both
Link is UP, administrative state is UP
Thrash-limiting
Status Not Detected, Action link-down, Timeout 60(s)
Hardware is Ethernet, address is 0000.cd24.daeb
index 5001 metric 1 mru 1500
<UP,BROADCAST,RUNNING,MULTICAST>
current duplex half, current speed 100
configured duplex auto, configured speed auto, configured polarity auto
current ecofriendly lpi
configured ecofriendly lpi
SNMP link-status traps: Sending (Suppressed after 20 traps in 60 sec.)
input packets 2396, bytes 324820, dropped 0, multicast packets 2370
output packets 73235, bytes 406566, multicast packets 7321 broadcast packets 7
Time since last state change: 0 days 16:35:52
...
Interface lo
Scope: both
Link is UP, administrative state is UP
Hardware is Loopback
index 1 metric 1
<UP,LOOPBACK,RUNNING>
SNMP link-status traps: Disabled
input packets 0, bytes 0, dropped 0, multicast packets 0
output packets 0, bytes 0, multicast packets 0 broadcast packets 0
Time since last state change: 0 days 16:35:52
Interface vlan1
Scope: both
Link is DOWN, administrative state is UP
Hardware is VLAN, address is 0000.cd24.daa8
index 201 metric 1 mtu 1500
arp ageing timeout 300
<UP,BROADCAST,MULTICAST>
VRF Binding: Not bound
SNMP link-status traps: Disabled
Bandwidth 1g
input packets 0, bytes 0, dropped 0, multicast packets 0
output packets 29, bytes 1334, multicast packets 0 broadcast packets 0
Time since last state change: 0 days 05:36:40