1096
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
C613-50057-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
A
UTHENTICATION
C
OMMANDS
AUTH
-
WEB
-
SERVER
PING
-
POLL
INTERVAL
auth-web-server ping-poll interval
Overview
This command is used to change the ping poll interval. The interval specifies the
time period between pings when the supplicant (client device) is reachable.
Use the
no
variant of this command to reset to the default period for ping polling
(30 seconds).
Syntax
auth-web-server ping-poll interval <
1-65535
>
no auth-web-server ping-poll interval
Default
The interval for ping polling is 30 seconds by default.
Mode
Global Configuration
Examples
To set the interval of ping polling to
60
seconds, use the following commands:
awplus#
configure terminal
awplus(config)#
auth-web-server ping-poll interval 60
To set the interval of ping polling to the default (30 seconds), use the following
commands:
awplus#
configure terminal
awplus(config)#
no auth-web-server ping-poll interval
Validation
Commands
show auth-web
show auth-web-server
show running-config
Parameter
Description
<
1-65535
>