C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
1819
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
P
ING
-P
OLLING
C
OMMANDS
NORMAL
-
INTERVAL
normal-interval
Overview
This command specifies the time period between pings when the device is
reachable.
The
no
variant of this command resets the time period to the default of 30 seconds.
Syntax
normal-interval <
1-65536
>
no normal-interval
Default
The default is 30 seconds.
Mode
Ping-Polling Configuration
Examples
To specify a time period of 60 seconds between pings when the device is reachable
for ping-poll instance 45, use the commands:
awplus#
configure terminal
awplus(config)#
ping-poll 45
awplus(config-ping-poll)#
normal-interval 60
To reset the interval to the default of 30 seconds for ping-poll instance 45, use the
commands:
awplus#
configure terminal
awplus(config)#
ping-poll 45
awplus(config-ping-poll)#
no normal-interval
Related
Commands
critical-interval
fail-count
ping-poll
sample-size
show ping-poll
timeout (ping polling)
up-count
Parameter
Description
<
1-65536
>
Time in seconds between pings when the target is reachable.