292
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
C613-50057-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
L
OGGING
C
OMMANDS
LOG
(
FILTER
)
log email (filter)
Overview
This command creates a filter to select messages to be sent to an email address.
Selection can be based on the priority/ severity of the message, the program that
generated the message, the logging facility used, a sub-string within the message
or a combination of some or all of these.
The
no
variant of this command configures the device to no longer send log
messages to a specified email address. All configuration relating to this log target
will be removed.
Syntax
log email
<email-address>
[level
<level>
] [program
<program-name>
] [facility
<facility>
] [msgtext
<text-string>
]
no log email
<email-address>
[level
<level>
] [program
<program-name>
] [facility
<facility>
] [msgtext
<text-string>
]
Parameter
Description
<email-
address>
The email address to send logging messages to
level
Filter messages by severity level.
<
level
>
The minimum severity of message to send. The level can be specified as one of the following
numbers or level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies
System is unusable
1|alerts
Action must be taken immediately
2|critical
Critical conditions
3|errors
Error conditions
4|warnings
Warning conditions
5|notices
Normal, but significant, conditions
6|informational
Informational messages
7|debugging
Debug-level messages
program
Filter messages by program. Include messages from a specified program.