C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
1789
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
T
RIGGER
C
OMMANDS
TIME
(
TRIGGER
)
time (trigger)
Overview
This command specifies the time of day when the trigger is permitted to activate.
The after parameter specifies the start of a time period that extends to midnight
during which trigger may activate. By default the value of this parameter is
00:00:00 (am); that is, the trigger may activate at any time. The
before
parameter
specifies the end of a time period beginning at midnight during which the trigger
may activate. By default the value of this parameter is 23:59:59; that is, the trigger
may activate at any time. If the value specified for
before
is later than the value
specified for
after
, a time period from
“
after
”
to
“
before
”
is defined, during which
the trigger may activate. This command is not applicable to time triggers (
type
time
).
The following figure illustrates how the
before
and
after
parameters operate.
Syntax
time {[after <
hh:mm:ss
>] [before <
hh:mm:ss
>]}
Mode
Trigger Configuration
00:00
06:00
12:00
18:00
00:00
00:00
06:00
12:00
18:00
00:00
00:00
06:00
12:00
18:00
00:00
00:00
06:00
12:00
18:00
00:00
BEFORE=08:00
AFTER=18:00
AFTER=18:00 BEFORE=08:00
AFTER=08:00 BEFORE=18:00
Period when trigger may activate.
Key:
Period when trigger may not activate.
TRG_02
Parameter
Description
after
<
hh:mm:ss
>
The earliest time of day when the trigger may be activated.
before
<
hh:mm:ss
>
The latest time of day when the trigger may be activated.