1878
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
C613-50057-01 REV A
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
S
TACKING
C
OMMANDS
SHOW
STACK
Pending ID
The pending stack member ID. This can be changed by the
stack renumber
command. If there is no pending ID, the “
-
”
symbol will display.
Stack port
status
The status of the stack port. This can be:
•
Down
•
Neighbor incompatible
•
Discovering neighbor
•
Learned neighbor
Priority
Stack member master election priority (between 1 and 255)
Note that the lowest number has the highest priority.
Product Type
Stack member product type. For example, IX5- 28GPX.
Provisioned
Indicates that the stack position is provisionally configured,
i.e. ready to accept a particular switch type into the stack.
Resilienc
y link
status
The current status of the resiliency link. The status can be
one of:
•
Not configured
(Master or Member).
•
Configured
(Master only).
•
Successful
:
Successfully receiving healthchecks from the Active Master.
•
Failed
(Member only):
Not receiving any healthchecks from the Active Master.
•
Stopped
:
The resiliency link is configured, but is inactive. This may
occur in a Disabled Master stack, for example if the Disabled
Master Monitoring feature is not used.
Table 49-5: Parameters in the output from the
show stack detail
command
Parameter
Description