156 Parameters
Start inhibit status word. This word specifies the source of the
inhibiting signal that is preventing the drive from starting.
The conditions marked with an asterisk (*) only require that
the start command is cycled. In all other instances, the
inhibiting condition must be removed first.
See also parameter
, bit 1.
This parameter is read-only.
-
0000h…FFFFh
Start inhibit status word.
1 = 1
Speed control status word.
This parameter is read-only.
-
0000h…FFFFh
Speed control status word.
1 = 1
No.
Name/Value
Description
Def/FbEq16
Bit
Name
Description
0
Not ready run
1 = DC voltage is missing or drive has not been parametrized
correctly. Check the parameters in groups 95 and 99.
1
Ctrl location changed
* 1 = Control location has changed
2
SSW inhibit
1 = Control program is keeping itself in inhibited state
3
Fault reset
* 1 = A fault has been reset
4
Lost start enable
1 = Start enable signal missing
5
Lost run enable
1 = Run enable signal missing
6
Reserved
7
STO
1 = Safe torque off function active
8
Current calibration
ended
* 1 = Current calibration routine has finished
9
ID run ended
* 1 = Motor identification run has finished
10
Reserved
11
Em Off1
1 = Emergency stop signal (mode off1)
12
Em Off2
1 = Emergency stop signal (mode off2)
13
Em Off3
1 = Emergency stop signal (mode off3)
14
Auto reset inhibit
1 = The autoreset function is inhibiting operation
15
Jogging active
1 = The jogging enable signal is inhibiting operation
Bit
Name
Description
0
Zero speed
1 = Drive has been running below zero speed limit (par.
)
for a time defined by parameter
1
Forward
1 = Drive is running in forward direction above zero speed limit
(par.
)
2
Reverse
1 = Drive is running in reverse direction above zero speed limit
(par.
)
3…6
Reserved
7
Any constant speed
request
1 = A constant speed or frequency has been selected; see par.
8…15
Reserved
ACS580 FW.book Page 156 Wednesday, September 21, 2016 9:48 PM