272 Parameters
36
Peak value and amplitude logger settings.
See also section
(page
).
Selects the signal to be monitored by the peak value logger.
The signal is filtered using the filtering time specified by
parameter
The peak value is stored, along with other pre-selected
signals at the time, into parameters
.
The peak value logger can be reset using parameter
. The logger is also reset whenever the signal
source is changed. The date and time of the last reset are
stored into parameters
and
respectively.
Not selected
None (peak value logger disabled).
0
Motor speed used
(page
1
Reserved
2
Output frequency
(page
3
Motor current
4
Reserved
5
Motor torque
).
6
DC voltage
(page
).
7
Output power
). 8
Reserved
9
Speed ref ramp in
(page
10
Speed ref ramp out
(page
).
11
Speed ref used
12
Torque ref used
). 13
Freq ref used
(page
).
14
Reserved
15
Process PID out
(page
16
Source selection (see
on page
). -
Peak value logger filtering time. See parameter
.
2.00 s
0.00…120.00 s
Peak value logger filtering time.
100 = 1 s
Selects the signal to be monitored by amplitude logger 2. The
signal is sampled at 200 ms intervals.
The results are displayed by parameters
. Each
parameter represents an amplitude range, and shows what
portion of the samples fall within that range.
The signal value corresponding to 100% is defined by
parameter
Amplitude logger 2 can be reset using parameter
. The logger is also reset whenever the signal
source or scaling is changed. The date and time of the last
reset are stored into parameters
respectively.
For the selections, see parameter
Defines the signal value that corresponds to 100% amplitude. 100.00
0.00…32767.00
Signal value corresponding to 100%.
1 = 1
No.
Name/Value
Description
Def/FbEq16